Indoor Tight-Buffered Fiber Optic Cable indoor cable

Nexora

Indoor Tight-Buffered Fiber Optic Cable

Flame-retardant tight-buffered indoor fiber optic cable for riser and plenum runs, patch panels and short-haul distribution inside buildings.

Fiber Type

Single mode OS2 / multimode OM3, OM4

Application

Indoor distribution, patch panels, data centers

Jacket Material

LSZH / PVC

Product Notes

  • Easy strip and terminate
  • Flame-retardant jacket
  • Riser and plenum options
Get A Quote

Specifications

Fiber type, connector, test data, packaging proof and sample-kit notes are kept in the same quote sheet.

Fiber TypeSingle mode OS2 / multimode OM3, OM4
Fiber Count2-144 cores
Buffer TypeTight buffer, 900 um
Jacket MaterialLSZH / PVC
Fire RatingRiser (OFNR) / plenum (OFNP)
ApplicationIndoor distribution, patch panels, data centers
Bend Radius10 x cable diameter (static); 20 x cable diameter (installation)
Warranty12 months from shipment date

Application Notes

Indoor fiber optic cable for riser, plenum and in-building distribution

Inside a building, an indoor fiber optic cable has to do two jobs at once: stay easy to terminate at patch panels, wall outlets and distribution frames, and match the fire rating of the space it runs through. A loose-tube cable is built for long outdoor spans; inside a riser or plenum it adds stripping and splicing steps at every connection point. This tight-buffered indoor fiber optic cable is aimed at that short-haul distribution work, where termination speed and jacket rating decide the project more than reach.

The buyer problem: one jacket rating for two different building zones

The most expensive mistake on an indoor fiber project is not the cable price, it is pulling the wrong jacket rating. A riser run between floors and a plenum air-handling space are governed by different fire requirements, and a cable that passes one zone can fail inspection in the other. When that happens after the cable is already installed, the cost is not the cable: it is re-pulling the run, re-terminating both ends, and the schedule slip that follows. Buyers who order one jacket rating for the whole building to simplify purchasing often create exactly this problem.

How this tight-buffered cable solves it

This cable is supplied in two jacket versions so the rating can be matched to the zone instead of averaged across the building. Each fiber carries a 900 µm tight buffer, so the buffer sits directly on the fiber and can be stripped and terminated without the loose-tube steps of separating tubes and cleaning gel. For a riser shaft, order the riser-rated jacket; for an air-handling plenum space, order the plenum-rated version. The same cable family covers both, which keeps the fiber count, buffer type and termination method consistent across the project.

Specifications

ParameterValue
Fiber typeSingle mode OS2, or multimode OM3 / OM4
Fiber count2 to 144 cores
Buffer typeTight buffer, 900 µm
Jacket materialLSZH or PVC
Fire ratingRiser (OFNR) or plenum (OFNP)
Bend radius10 × cable diameter (static); 20 × cable diameter (during installation)
ApplicationIndoor distribution, patch panels, data centers
Warranty12 months from shipment date

The static bend radius of 10 × cable diameter applies to the cable at rest in trays and conduits. During pulling and installation, keep the bend radius at 20 × cable diameter or wider, and avoid sharp edges in trays and conduits. Leave enough slack at each termination point so the tight-buffered fibers can be stripped and terminated without strain.

Jacket and fiber options

The jacket material and fire rating are ordered as a pair, so the cable matches both the building zone and the material requirement of the project:

Building zoneFire ratingJacket material
Vertical shaft between floorsRiser (OFNR)LSZH or PVC
Air-handling plenum spacePlenum (OFNP)LSZH or PVC

Fiber type is selected separately from the jacket: single mode OS2 for long-reach links, or multimode OM3 / OM4 for shorter in-building runs. Confirm the fiber type, jacket material and fire rating together when you request a quote, since the three are specified independently.

What to check when you compare

  • Fiber count: match the port plan plus a margin for future growth; this cable covers 2 to 144 cores.
  • Fiber type: confirm OS2, OM3 or OM4 against your link budget and reach.
  • Fire rating: confirm the rating required by the building zone, riser (OFNR) for vertical shafts and plenum (OFNP) for air-handling spaces.
  • Buffer type: tight buffer suits direct stripping and termination; loose tube suits long outdoor spans.
  • Bend radius: check both the static value and the installation value against your tray and conduit routing.

Quality control and manufacturing

This indoor fiber optic cable is produced in a Shenzhen facility with 12 production lines and more than 30 QC stations covering incoming material, component, in-process, functional, visual, final and packaging inspection. Nexora has delivered more than 500 OEM/ODM projects across 50+ countries. These figures describe the manufacturer's overall capacity and project record, not the capacity reserved for this cable model; confirm the production slot for your order quantity when you request a quote.

Packaging, lead time and ordering

Cable is supplied on standard reels with the length and marking agreed at order confirmation. Typical production lead time is 15 to 25 working days after order confirmation, depending on fiber count, jacket rating and order quantity; confirm the exact schedule for your order when you request a quote. Custom lengths and printed marking are supported for OEM and ODM projects. Warranty is 12 months from shipment date and covers material and manufacturing defects reported within that period; share the order details and defect description with our team to start a claim.

Frequently asked questions

What fiber count should I order?

Choose the count that matches your port plan plus a margin for future growth. This indoor fiber optic cable is available from 2 to 144 cores.

Which fiber type should I choose?

Single mode OS2 suits long-reach links, while multimode OM3 and OM4 suit shorter in-building runs. Confirm the fiber type against your link budget and reach before ordering.

What is the difference between riser and plenum jackets?

Riser and plenum are building-zone ratings. A riser-rated jacket (OFNR) suits vertical runs between floors, while a plenum-rated jacket (OFNP) is intended for air-handling spaces. Confirm the rating required by your local building code before ordering.

What is the minimum order quantity?

MOQ depends on fiber count and jacket rating. Share your required fiber count, jacket rating and total length, and our team will confirm the MOQ and unit price for your order.

How is the cable packed and shipped?

Cable is supplied on standard reels with the length and marking agreed at order confirmation. Packing and shipping terms are confirmed with the quotation for your order.

What payment terms do you accept?

Payment terms are confirmed per order and stated on the quotation. Contact our team with your order details to confirm the applicable terms.

Can I get a sample or a custom length?

Custom lengths and printed marking are supported for OEM and ODM projects. Share your required length and marking with our team when you request a quote.

Is this cable suitable for data centers?

Yes. The compact, flexible construction and easy termination make it suitable for indoor distribution, patch panels and data center runs. For data center use, confirm the jacket rating required by your facility's fire code before ordering.

What warranty do you offer?

Warranty is 12 months from shipment date and covers material and manufacturing defects reported within that period. Share your order details with our team to start a claim.

Request product details

Tell us your fiber count, fiber type, jacket rating (riser or plenum), required length and any printed marking, and our team will confirm availability and lead time for your project.

Request a quote

Tags

Related Fiber Products

Get A Quote

Send fiber type, connector, quantity, application and packaging requirement. The response can include test data and sample-kit notes.

OEM & Customization

Connector types, fiber counts, cable lengths, jacket materials and packaging can be configured to your project specification.

Technical Support

Our engineering team helps you confirm product selection, installation details and documentation before you place the order.

Quality & Testing

Every order is inspected before shipment, and test data or inspection reports can be provided with the goods on request.

Product Inquiry
◆