LSZH vs PVC Jacket: Indoor Fire-Rating Choice
PVC burns with dense smoke; LSZH costs a little more and keeps the escape route visible. How OFNR, OFNP and LSZH ratings map to buildings, and what to write on the order.
The optical performance of a jacket is identical; its behavior in a fire is not. Jacket choice is the one cable decision a building inspector reads first, and it is decided before the first meter is pulled. For an indoor tight-buffered cable or any cord order, the jacket line on the order sheet is a code decision.
The rating ladder
| Jacket | Typical rating | Best fit | Fire behavior |
|---|---|---|---|
| PVC | General indoor (CM/OFNR variants) | Offices and equipment rooms | Dense smoke, halogen acid gas |
| LSZH | IEC 60332-1/-3 | Risers, public corridors, tunnels, enclosed routes | Low smoke, no halogen acid gas |
| Plenum (OFNP) | North American plenum | Air-handling spaces | Strictest common rating |
| Outdoor PE | Outdoor only | Outside plant | Not permitted indoors |
What codes usually ask
- Risers require a riser-rated jacket (OFNR or equivalent fire-rated LSZH per local code).
- Air-handling plenums require plenum-rated OFNP in North American practice.
- Public and enclosed routes increasingly specify LSZH, especially in EU-influenced markets.
- Always verify the local clause. Ratings differ between markets; the inspector's edition governs, not the catalog.
Ordering notes the jacket changes
- LSZH jackets run slightly larger in OD; tray fill and bend-radius planning stay routine.
- Optical parameters do not move: ≤0.3 dB typical / ≤0.5 dB max IL and UPC ≥50 dB / APC ≥60 dB RL for OS2 cords regardless of jacket.
- State the rating on the order line itself, so the packing list and the inspector see the same words.
Key specifications at a glance
| Parameter | Typical value |
|---|---|
| Jacket options | PVC, LSZH, OFNR, OFNP; PE outdoor only |
| Cable types | Tight-buffered indoor, distribution, patch cords |
| Insertion loss (connectorized ends) | ≤0.3 dB typical / ≤0.5 dB max (1310/1550 nm) |
| MOQ | 1,000 pcs (adapters) / 100 pcs (cords); cable per drum |
| Lead time | 7–15 working days after deposit |
| Payment | 30% T/T deposit, balance before shipment |
| Warranty | 12 months from shipment date |
Rating names follow common market usage; local code clauses and the shipped datasheet govern each project.
Buyer FAQ
Which is stricter, LSZH or OFNP?
OFNP is the strictest North American rating. LSZH is the European-style answer for smoke and halogens; the two are selected by code environment, not by a single scale.
Can LSZH replace plenum cable?
Only where the local authority accepts it. In North American plenums the answer is usually no; elsewhere LSZH often satisfies riser and public-route clauses.
Does the jacket affect optical performance?
No. IL and RL are set by the fiber and the ferrules; the jacket decision is mechanical and fire-safety only.